Abstract

The primary objective of the present study was to determine the seasonal dynamics of ciliates in activated sludge. Studies were carried out in order to verify the hypothesis that fertility of a habitat may significantly influence the seasonal dynamics of the abundance of ciliates, as well as the number and intensity of correlations between physic-chemical parameters and ciliates. It seems that the values of numbers of ciliates were seasonally changeable. The highest numbers of ciliates were found in spring and summer, however the lowest numbers of ciliate communities were noted in winter. The studies showed that protozoa community is determined by ammonia mainly in summer. In spring and winter additional factors may be important. Probably suspended solid, total organic carbon and concentration of appropriate food (bacteria and flagellates) are the major regulator of abundance of ciliates.
Go to article

Abstract

FA discharged from the wastewater treatment plant were extracted from purifi ed effl uents for the quantitative and qualitative analysis. The treated sewage from municipal treatment plants was acidifi ed to pH <2 and extracted with ion exchange resins in a laboratory column. After desorption with NH4 OH, the fulvic acids were condensed under vacuum and tested for mass performance, UV-VIS light spectra, IR absorption spectra, elementary composition and other elements. Their structure was analysed and compared to FA present in surface waters and in sewage treated in other sewage treatment plants based on the authors’ own research and the literature data. The concentration of FA in the treated sewage was 5.2 mg/L. There is a high interdependence between the IR spectrum analysis in the visible light and the elementary composition of FA extracted from different environments, confi rming the conclusions pertaining to the structure and properties of the acids being tested. The longer sewage is subjected to a biological treatment process, the greater the degree of aromatic condensation and humus maturity of the FA contained within it. FA contained in the sewage treated in the three biological sewage treatment plants have the ratio A2 /A3 (the ratio of the absorbance of light with the wavelength of 250 and 300 nm) equal to the value 1.7. There is a high interdependence between the IR spectrum analysis in the visible light and the elementary composition of FA extracted from different environments, confi rming the conclusions pertaining to the structure and properties of the acids being tested.
Go to article

Abstract

In this work microbiological air pollution at several commune sewage treatment plants (capacity up to 15,000 PE) was investigated. The bioreactors in all plants had a covered construction. The air samples were taken indoors as well as outdoors (both on the windward and leeward side) during different seasons. The samples were collected using the collision method. The presence of indicator organisms in the samples was determined according to the Polish Standards. Identification of individual indicators was performed on solid selective-differentiating substrates. To verify the presence of bacteria from Salmonella, Shigella, coliforms and enterococci species, the colonies observed on the MacConkey substrate were then sifted onto SS and Endo substrates. At all facilities (with one exception) the average CFU for the total number of bacteria and fungi did not exceed 1000/m3, which is the limit set by the Polish Standards for a pollution-free atmospheric air. Bacteria and fungi concentrations, observed at windward and leeward sides of all plants, were relatively low (<100 CFU/m3 and <1000 CFU/m3, respectively) and comparable. A sewage collection point had only a slight impact on the bioaerosol emission. The concentration of microorganisms in the immediate vicinity of covered reactors (aeration chambers) was rather low and remained below the limits sets by the Polish Standards at three facilities. The CFU of individual indicators, measured in rooms accessible for the personnel, was comparable to the CFU in technological rooms. However some indicators, e.g. a number of Actinomycetes, were significantly higher and reached >100 CFU/m3, which means significant air pollution. Similarly, the CFU of hemolytic bacteria had nonzero values. The only place where higher concentrations of bioaerosol were found was the centrifuge room, where digested sludge was dewatered. The number of fungi stayed below the limits there, but the amount of heterotrophic and hemolytic bacteria exceeded the limits and reached the values of ~10000 CFU/m3 and 800 CFU/m3, respectively; it means that the personnel working in this area is exposed to microbiological agents.
Go to article

Abstract

The study was aimed at evaluating microbial contamination on the premises of the sewage treatment plant by determining the concentrations of selected groups of airborne microorganisms. Another objective was to determine the antibiotic sensitivity patterns of isolated strains of staphylococci. The research was conducted in a seasonal cycle, by the impaction method using Merck MAS-100 air sampler. Samples were collected at six sites, each representing a different stage of sewage treatment. The susceptibility of isolated staphylococci was assessed with the disc-diffusion method, following the recommendations of the EUCAST. The results indicate that the microbial population in the air of the investigated area was dominated by mold fungi, whose highest average concentration was recorded at site IV located near the final clarifier (7672 CFU•m-3). Heterotrophic bacteria and mannitol-positive staphylococci were the most numerous at locations where sewage undergoes primary treatment. In each subseuqent stage the number of microorganisms emitted into the air from the sewage was lower. Antibiograms show that more than 50% of Staphylococcus spp. exhibited resistance to penicillin and 20% to rifampicin. In addition, 90% of the analyzed strains were sensitive to other antibiotics. The fungal community included the following genera: Cladosporium, Fusarium, Alternaria, Penicillium, Aspergillus, Aureobasidium, and Acremonium.The highest air contamination with all studied groups of microorganisms was recorded at the locations where mechanical sewage treatment was performed. During the subsequent stages lower numbers of heterotrophic bacteria were emitted into the air. The air in the investigated sewage treatment plant did not contain multidrug-resistant staphylococci.
Go to article

Abstract

This paper shall present and explain the key aspects related to the issue of combined heat and power generation (CHP – Combined Heat and Power or Cogeneration). The cooperation with the water treatment plant launched allowed a closer look at the described technology as well as allowed the analyses and survey. The survey on the efficacy of the selected components of the cogeneration system was based on two cogeneration units fuelled with biogas produced in the sewage fermentation.
Go to article

Abstract

Due to insufficient operation efficiency, the studied treatment plant has undergone modernization. The aim of this study was to assess whether this modernization improved quality of the STP effluent and water quality in the receiver. The research period of fifty months covered time before and after the modernization. Samples were collected in four sites – upstream and downstream of the STP and by the sewage discharge. Electrolytic conductivity, water temperature and pH were measured onsite. Chemical analyzes were based on ion chromatography and determined the concentration of NH4+, NO3-, NO2-, PO43-, TDS. Microbiological analysis comprised serial dilutions to assess the number of mesophilic and psychrophilic bacteria and membrane filtration to enumerate E. faecalis, total and fecal coliforms as well as total and fecal E. coli. Values of most analyzed parameters did not improve after the modernization, or improved for a very short period of time (NH4+), while some of them even increased, such as PO43-, total and thermotolerant coliforms and E. coli. The maximum value of thermotolerant E. coli reached nearly 7 million CFU/100 ml and was observed after modernization. Also at the sites situated downstream of the STP some of analyzed parameters increased. The conducted modernization did not improve the quality of treated sewage and even a further deterioration was observed. It could have been a result of rapidly growing number of tourists visiting the studied area, thus generating large amounts of sewage causing STP overload coupled with poor water and wastewater management. Significant percentage of unregistered tourists hinders proper assessment of the STP target efficiency.
Go to article

Abstract

Carbon dioxide sequestration and its long-term immobilisation in biomass is recently an extremely significant problem. Its greatest reserves occur in forests growing all over the globe. A human being, through their conscious action, ought to affect, among other things, the amount of carbon dioxide discharged into the atmosphere and its rational management. Here, quite a good solution seems to be the immobilisation of CO2 in biomass of plants, and in particular, in trees, characterised by their longevity, which are used most frequently for that purpose. Such carbon dioxide management allows for its several-decade immobilisation within living plants, while a further processing of wood mass allows for halting it for consecutive years in products manufactured. Additionally, in the case when within a selected land planted with trees the effluent irrigation is being carried out, simultaneous sewage treatment is also an advantage. By using plants characterised by intense increment in biomass within facilities, also biogens occurring in effluents may be effectively removed. In the analysed case, sewage treatment consisted in entry of household sewage into a prepared surface which was previously subject to mechanical purification. All the sections were sown with grass mixture and plantings of poplar were used. Observations were made during the period of 17 years. The effluents entered onto the surface of the sections and the effluents outflowing from the facility were subject to a physicochemical analysis in order to determine the operational efficiency of a plant - soil treatment system. Also, a threefold inventory of a forest stand was made in order to determine the increment in trees. The last inventory was made in 2014. Based on dendrological characteristics, the average volume of wood mass obtained from the land irrigated with effluents was assessed. A rational management of effluents on the grounds without any central drainage allows for a parallel solution to some problems. First of all, purification of effluents in a natural environment by closing the matter cycle, and additionally contributing to the limitation of carbon dioxide emission by its halting in plant biomass.
Go to article

Abstract

The paper presents preliminary results of investigations on a relationship between turbidity and other quality parameters in the SBR plant effluent. The laboratory tests demonstrated a high correlation between an effluent turbidity and a total suspended solids (TSS) concentration as well as between TSS and COD. Such a relationship would help to continuously monitor and control quality of a wastewater discharge using turbidity measurement.
Go to article

Abstract

The aim of this study was to determine the impact of the temperature of wastewater in a biological reactor with activated sludge and the BOD5/N-NH4 ratio in the influent to the treatment plant on nitrification efficiency and the concentration of ammonium nitrogen in treated wastewater. Tests were carried out in a household wastewater treatment plant which collects and treats sewage from a school building and a teacher’s house. During the 3-year study, large fluctuations in the sewage temperature in bioreactor were noted which was closely related to the ambient temperature. There were also large fluctuations in the concentration of organic matter and the concentration of ammonium nitrogen in inflowing sewage. The influence of wastewater temperature in the bioreactor and the BOD5/N-NH4 ratio on the concentration of ammonium nitrogen in treated wastewater was determined using Pearson’s linear correlation. A statistical analysis showed that a 1°C decrease in the temperature of wastewater in the bioreactor increased the concentration of ammonium nitrogen in treated wastewater by 2.64 mgN-NH4·L-1. Moreover, it was found that nitrification depended on the ratio of BOD5 to the concentration of ammonium nitrogen in wastewater flowing into the bioreactor. An increase in the BOD5/N-NH4 ratio by 1 value led to a 5.41 mgN-NH4·L-1 decrease in the concentration of ammonium nitrogen.
Go to article

Abstract

The aim of the study was to evaluate the possibility of applying different methods of data mining to model the inflow of sewage into the municipal sewage treatment plant. Prediction models were elaborated using methods of support vector machines (SVM), random forests (RF), k-nearest neighbour (k-NN) and of Kernel regression (K). Data consisted of the time series of daily rainfalls, water level measurements in the clarified sewage recipient and the wastewater inflow into the Rzeszow city plant. Results indicate that the best models with one input delayed by 1 day were obtained using the k-NN method while the worst with the K method. For the models with two input variables and one explanatory one the smallest errors were obtained if model inputs were sewage inflow and rainfall data delayed by 1 day and the best fit is provided using RF method while the worst with the K method. In the case of models with three inputs and two explanatory variables, the best results were reported for the SVM and the worst for the K method. In the most of the modelling runs the smallest prediction errors are obtained using the SVM method and the biggest ones with the K method. In the case of the simplest model with one input delayed by 1 day the best results are provided using k-NN method and by the models with two inputs in two modelling runs the RF method appeared as the best.
Go to article

Abstract

The aim of the research was the evaluation of wastewater management in terms of stability and efficiency of wastewater treatment, using statistical quality control. For this purpose, the analysis of the operation and operation of the “Kujawy” Sewage Treatment Plant was made, which is one of the most important and largest sewage management facilities in the city of Cracow. This assessment was done using control charts x for 59 observations. The analysed research period covered the multi-year from 2012 to 2016. Five key pollutant indicators were used to evaluate the work of the tested object: BOD5, CODCr, total suspension, total nitrogen and total phosphorus. In the case of the majority of them, based on the analysis of control charts, full stability of their removal was found in the tested sewage management facility. The exception was total nitrogen, for which periods of disturbed stability of its disposal processes were noted. Analysis of the effectiveness of wastewater treatment showed each time that the required efficiency of reduction of the analysed pollution indicators in the “Kujawy” Sewage Treatment Plant was achieved.