Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 44
items per page: 25 50 75
Sort by:

Abstract

The article describes the method of controlling the recovered grade based on measuring the intensity of volume ultrasonic oscillations and Lamb waves covering a fixed distance through the test medium and on a metal plate contacting the test medium at various time points of deliberate motion of ground materials. The authors suggest a method of determining density of ground ore particles in the pulp periodically after isolating the pulp flow in the vertical part of the measuring vessel based on measuring attenuation change values in Lamb waves covering a fixed distance on a plate contacting the medium under study and high frequency volume ultrasonic oscillations that have come through it within a certain time period. There are given dependencies of amplitudes of measuring channels based on volume ultrasonic oscillations and surface Lamb waves, size distribution according to solid phase pulp particles for various types of ores under study, a set of curves for determining the recovered grade with regard to various types of ores under study.
Go to article

Abstract

Ultrasound is used for breast cancer detection as a technique complementary to mammography, the standard screening method. Current practice is based on reflectivity images obtained with conventional instruments by an operator who positions the ultrasonic transducer by hand over the patient’s body. It is a non-ionizing radiation, pain-free and not expensive technique that provides a higher contrast than mammography to discriminate among fluid-filled cysts and solid masses, especially for dense breast tissue. However, results are quite dependent on the operator’s skills, images are difficult to reproduce, and state-of-the-art instruments have a limited resolution and contrast to show micro-calcifications and to discriminate between lesions and the surrounding tissue. In spite of their advantages, these factors have precluded the use of ultrasound for screening. This work approaches the ultrasound-based early detection of breast cancer with a different concept. A ring array with many elements to cover 360◦ around a hanging breast allows obtaining repeatable and operator-independent coronal slice images. Such an arrangement is well suited for multi-modal imaging that includes reflectivity, compounded, tomography, and phase coherence images for increased specificity in breast cancer detection. Preliminary work carried out with a mechanical emulation of the ring array and a standard breast phantom shows a high resolution and contrast, with an artifact-free capability provided by phase coherence processing.
Go to article

Abstract

This paper presents an analysis of use of ultrasonic standing wave in cell separation from bodily fluids based on the example of erythrocyte separation from plasma. It describes movement of red blood cells in plasma under the influence of the acoustic field (whose forces result from interaction of red blood cells with plasma as the vibrating medium) and under the influence of resistance forces in Stokes’ and Oseen’s approximation. The general properties of solutions of the motion equation are given. The solutions for the parameters of the ultrasonic wave and blood cells which are interesting in terms of practical applications in medical diagnostics are discussed. Time constants of the cell transportation to the regions of stable equilibrium in the field of ultrasonic standing wave are estimated. The formulas which determine the time needed to obtain the assumed concentration increase in plasma in nodes and/or anti-nodes of the standing wave are derived.
Go to article

Abstract

The issue of maximizing penetration depth with concurrent retaining or enhancement of image resolution constitutes one of the time invariant challenges in ultrasound imaging. Concerns about potential and undesirable side effects set limits on the possibility of overcoming the frequency dependent attenuation effects by increasing peak acoustic amplitudes of the waves probing the tissue. To overcome this limitation a pulse compression technique employing 16 bits Complementary Golay Sequences (CGS) Code was implemented at 4 MHz. In comparison with other, earlier proposed, coded excitation schemes, such as chirp, pseudo-random chirp and Barker codes, the CGS allowed virtually side lobe free operation. Experimental data indicate that the quality — resolution, signal penetration and contrast dynamics — of CGS images is better than the one obtain for standard ultrasonography using short burst excitation.
Go to article

Abstract

Synthetic aperture (SA) technique is a novel approach to present day commercial systems and has previously not been used in medical ultrasound imaging. The basic idea of SA is to combine information acquired simultaneously from all directions over a number of emissions and to reconstruct the full image from these data. The paper presents the multi-element STA (MSTA) method for medical ultrasound imaging. The main difference with the STA approach is the use of a few elements in the transmit mode in contrast to a single element aperture. This allows increasing the system frame rate, decreasing the number of emissions, and provides the best compromise between the penetration depth and lateral resolution. Besides, a modified MSTA is proposed with a corresponding RF signal correction in the receive mode, which accounts for the element directivity property. In the experiments a 32-element linear transducer array with 0.48 mm inter-element spacing and a burst pulse of 100 ns duration were used. Two elements wide transmission aperture was used to generate an ultrasound wave covering the full image region. The comparison of 2D ultrasound images of a tissue mimicking phantom obtained using the STA and MSTA methods is presented to demonstrate the benefits of the second one.
Go to article

Abstract

The paper presents the optimization problem for the multi-element synthetic transmit aperture method (MSTA) in ultrasound imaging applications. The optimal choice of the transmit aperture size is made as a trade-off between the lateral resolution, penetration depth and the frame rate. Results of the analysis obtained by a developed optimization algorithm are presented. The maximum penetration depth and lateral resolution at given depths are chosen as optimization criteria. The results of numerical experiments carried out in MATLAB® using synthetic aperture data of point reflectors obtained by the FIELD II simulation program are presented. The visualization of experimental synthetic aperture data of a tissue mimicking phantom and in vitro measurements of the beef liver performed using the SonixTOUCH Research system are also shown.
Go to article

Abstract

To design breast ultrasound scanning systems or to test new imaging methods, various computer models are used to simulate the acoustic wave field propagation through a breast. The computer models vary in complexity depending on the applied approximations. The objective of this paper is to investigate how the applied approximations affect the resulting wave field. In particular, we investigate the importance of taking three-dimensional (3-D) spatial variations in the compressibility, volume density of mass, and attenuation into account. In addition, we compare four 3-D solution methods: a full-wave method, a Born approximation method, a parabolic approximation method, and a ray-based method. Results show that, for frequencies below 1 MHz, the amplitude of the fields scattering off the compressibility or density contrasts are at least 24 dB higher than the amplitude of the fields scattering off the attenuation contrasts. The results also show that considering only speed of sound as a contrast is a valid approximation. In addition, it is shown that the pressure field modeled with the full-wave method is more accurate than the fields modeled using the other three methods. Finally, the accuracy of the full-wave method is location independent whereas the accuracy of the other methods strongly depends on the point of observation.
Go to article

Abstract

The pathological states of biological tissue are often resulted in attenuation changes. Thus, information about attenuating properties of tissue is valuable for the physician and could be useful in ultrasonic diagnosis. We are currently developing a technique for parametric imaging of attenuation and we intend to apply it for in vivo characterization of tissue. The attenuation estimation method based on the echoes mean frequency changes due to tissue attenuation dispersion, is presented. The Doppler IQ technique was adopted to estimate the mean frequency directly from the raw RF data. The Singular Spectrum Analysis technique was used for the extraction of mean frequency trends. These trends were converted into attenuation distribution and finally the parametric images were computed. In order to reduce variation of attenuation estimates the spatial compounding method was applied. Operation and accuracy of attenuation extracting procedure was verified by calculating the attenuation coefficient distribution using the data from the tissue phantom (DFS, Denmark) with uniform echogenicity while attenuation coefficient underwent variation.
Go to article

Abstract

A verification study of ultrasound transmission numerical simulation results with experiment results is presented in this paper. The work considers a model of a transformer tank which is filled with electro insulating oil. In the experiment, performed under laboratory conditions, an ultrasound wave is generated by a piezoelectric transducer that is fixed in the centre of the tank and measured by another transducer mounted inside the tank at three distances: 10, 20 and 30 cm from the sound source. The transducer is able to measure and generate acoustic waves in the ultrasound frequency band up to 1 MHz. The simulation considers numerical calculation of acoustic pressure distribution inside the tank in which acoustic source emits waves with frequency equal to 100 kHz. Verification analysis has confirmed consistency of the numerically calculated values with the measurement results.
Go to article

Abstract

The aim of the present theme issue was to study the influence of ultrasound enhancement on the kinetics of osmotic dehydration and the effect of convective drying from the point of view of drying time and quality of dried products. Apple fruit was used as the experimental material. The kinetics of osmotic dehydration with (UAOD) and without (OD) ultrasound enhancement were examined for 40% fructose and sorbitol solutions. The effective dehydration time of osmotic process was determined. Preliminary dehydrated samples with OD and UAOD were next dried convectively with (CVUS) and without (CV) ultrasound assistance. The influence of OD and UAOD on the kinetics of CV and CVUS drying was analysed. The parameters of water activity and colour change were measured for the assessment of product quality after drying process.
Go to article

Abstract

The temperature dependence of the particle size distribution (PSD) of the magnetic fluid with an additional biocompatible dextran layer was studied using a ultrasonic method. The measurements of the ultrasound velocity and attenuation were carried out as a function of the volume concentration of magnetite particles at temperatures ranging from 15°C to 40°C. In order to extract the PSD from ultrasonic measurements, the theoretical model of Vinogradov-Isakovich was used. The extraction of PSD from the ultrasonic data requires also the measurements the density and viscosity of the ferrofluid samples. The calculated PSD of the magnetic fluid with an additional biocompatible layer shows a greater thermal stability than that of a magnetic fluid with a single surfactant layer.
Go to article

Abstract

The paper presents the investigations aimed at the determination of the effect of time and wavelength of ultrasound field on the value of capillary suction time (CST), sludge thickening and dry matter of the excess sludge subjected to the process of stabilization. The investigations were carried out on the excess sludge which comes from communal waste treatment plant. The sludge was exposed to ultrasound field, using ultrasound generator with power of 1500 W, frequency of 20 kHz and amplitude 39.42 μm (which corresponded to the amplitude of 100%). Sonication of the sludge was carried out for different amplitudes and sonication times. The non-conditioned sludge and the sludge initially conditioned with ultrasound field were subjected to the process of stabilization in laboratory flasks (V = 0.5 dm3) for the period of 10 days. On each day, sludge thickening and dewatering capacities were determined. The sludge subjected to the effect of ultrasound field exhibited elevated levels of CST. However, the sonication time had positive effect on the increase in the degree of thickening for each of the amplitudes studied. Also, the process of stabilization positively affected final thickening and dewatering of the sludge.
Go to article

Abstract

In modern times, there are increasing requirements for products quality in every part of manufacturing industry and in foundry industry it is not different. That is why a lot of foundries are researching, how to effectively produce castings with high quality. This article is dealing with search of the influence of using different types of risers or chills on shrinkage cavity production in ductile iron castings. Differently shaped risers were designed using the Wlodawer´s modulus method and test castings were poured with and without combination of chills. Efficiency of used risers and chills was established by the area of created shrinkage cavity using the ultrasound nondestructive method. There are introduced the production process of test castings and results of ultrasound nondestructive reflective method. The object of this work is to determine an optimal type of riser or chill for given test casting in order to not use overrated risers and thus increase the cost effectiveness of the ductile iron castings production.
Go to article

Abstract

The aim of this article is to present a modern method of convective drying intensification caused by the external action of ultrasound. The purpose of this study is to discover the mechanism of ultrasonic interaction between the solid skeleton and the moisture in pores. This knowledge may help to explain the enhancement of drying mechanism affected by ultrasound, particularly with respect to biological products like fruits and vegetables. The experimental kinetics tests were conducted in a hybrid dryer equipped with a new ultrasonic generator. The drying kinetics curves determined on the basis of drying model developed by the author were validated with those by the ones obtained from experimental tests. The intensification of heat and mass transfer processes due to ultrasound induced heating effect and vibration effect are analysed. The obtained results allow to state that ultrasound makes drying processes more effective and enhance the drying efficiency of biological products without significant elevation of their temperature.
Go to article

Abstract

In this paper the influence of high power airborne ultrasound on drying biological material (Lobo apple) properties is considered. Apple samples were dried convectively at 75 ◦C and air flow of 2 m/s with and without ultrasound assist at 200W. During experiments, sun-drenched and not sun-drenched part of fruits were considered separately to show, how the maturity of the product influences dry material properties. Dried apple crisps in a size of small bars were subjected to compression tests during which acoustic emission (AE) was used. Analysis of AE and strength test results shows that correlations between received acoustic signals and sensory attributes (crispness, brittleness) of dried apples can be found. It was noted that ultrasound improved fruit brittleness in comparison with pure convective processes, where fruit maturity determines a kind of destruction and behaviour of dried apple crisps.
Go to article

Abstract

Commercially available cardiac scanners use 64–128 elements phased-array (PA) probes and classical delay-and-sum beamforming to reconstruct a sector B-mode image. For portable and hand-held scanners, which are the fastest growing market, channel count reduction can greatly decrease the total power and cost of devices. The introduction of ultra-fast imaging methods based on plane waves and diverging waves provides new insight into heart’s moving structures and enables the implementation of new myocardial assessment and advanced flow estimation methods, thanks to much higher frame rates. The goal of this study was to show the feasibility of reducing the channel count in the diverging wave synthetic aperture image reconstruction method for phased-arrays. The application of ultra-fast 32-channel subaperture imaging combined with spatial compounding allowed the frame rate of approximately 400 fps for 120 mm visualization to be achieved with image quality obtained on par with the classical 64-channel beamformer. Specifically, it was shown that the proposed method resulted in image quality metrics (lateral resolution, contrast and contrast-to-noise ratio), for a visualization depth not exceeding 50 mm, that were comparable with the classical PA beamforming. For larger visualization depths (80–100 mm) a slight degradation of the above parameters was observed. In conclusion, diverging wave phased-array imaging with reduced number of channels is a promising technology for low-cost, energy efficient hand-held cardiac scanners.
Go to article

Abstract

This paper presents and analyses the results of a simulation of the acoustic field distribution in sectors of a 1024-element ring array, intended for the diagnosis of female breast tissue with the use of ultrasonic tomography. The array was tested for the possibility to equip an ultrasonic tomograph with an additional modality - conventional ultrasonic imaging with the use of individual fragments (sections) of the ring array. To determine the acoustic field for sectors of the ring array with a varying number of activated ultrasonic transducers, a combined sum of all acoustic fields created by each elementary transducer was calculated. By the use of MATLAB software, a unique algorithm was developed, for a numerical determination of the distribution of pressure of an ultrasonic wave on any surface or area of the medium generated by the concave curvilinear structure of rectangular ultrasound transducers with a geometric focus of the beam. The analysis of the obtained results of the acoustic field distribution inside the ultrasonic ring array used in tomography allows to conclude that the optimal number of transducers in a sector enabling to obtain ultrasound images using linear echographic scanning is 32 ≤ n ≤ 128, taking into account that due to an increased temporal resolution of ultrasonic imaging, this number should be as low as possible.
Go to article

Abstract

The aim of this paper is to describe a non-invasive method of examination of the local pulse wave velocity. The measurements were carried out in the model of the artery immersed in a water tank. Two synchronized ultrasonic apparatus VED with the ultrasonic radio frequency echoes acquisition system were used for evaluation of the arterial elasticity. The zero-crossing method was used for determination of the diameter changes of the artery model. The transit time between the waveforms of instant artery diameter was measured at two points of the artery model, separated by the distance of 5 cm. The transit time was determined using the criteria of similarity of the first derivatives of the raising slopes of the curves describing instant vessel's diameter changes. The pulse wave velocity obtained by the proposed two-point method was compared with the results obtained by the one-point method based on the modified Bramwell-Hill relation.
Go to article

Abstract

Recently a new technology of piezoelectric transducers based on PZT thick film has been developed as a response to a call for devices working at higher frequencies suitable for production in large numbers at low cost. Eight PZT thick film based focused transducers with resonant frequency close to 40 MHz were fabricated and experimentally investigated. The PZT thick films were deposited on acoustically engineered ceramic substrates by pad printing. Considering high frequency and non-linear propagation it has been decided to evaluate the axial pressure field emitted (and reflected by thick metal plate) by each of concave transducer differing in radius of curvature - 11 mm, 12 mm, 15 mm, 16 mm. All transducers were activated using AVTEC AVG-3A-PS transmitter and Ritec diplexer connected directly to Agilent 54641D oscilloscope. As anticipated, in all cases the focal distance was up to 10% closer to the transducer face than the one related to the curvature radius. Axial pressure distributions were also compared to the calculated ones (with the experimentally determined boundary conditions) using the angular spectrum method including nonlinear propagation in water. The computed results are in a very good agreement with the experimental ones. The transducers were excited with Golay coded sequences at 35-40 MHz. Introducing the coded excitation allowed replacing the short-burst transmission at 20 MHz with the same peak amplitude pressure, but with almost double center frequency, resulting in considerably better axial resolution. The thick films exhibited at least 30% bandwidth broadening comparing to the standard PZ 27 transducer, resulting in an increase in matching filtering output by a factor of 1.4-1.5 and finally resulting in a SNR gain of the same order.
Go to article

Abstract

The main objective of this study is to develop an echocardiographic model of the left ventricular and numerical modeling of the speckles- markers tracking in the ultrasound (ultrasonographic) imaging of the left ventricle. The work is aimed at the creation of controlled and mobile environment that enables to examine the relationships between left ventricular wall deformations and visualizations of these states in the form of echocardiographic imaging and relations between the dynamically changing distributions of tissue markers of studied structures.
Go to article

Abstract

The main objective of this study is to improve the ultrasound image by employing a new algorithm based on transducer array element beam pattern correction implemented in the synthetic transmit aperture (STA) method combined with emission of mutually orthogonal complementary Golay sequences. Orthogonal Golay sequences can be transmitted and received by different transducer elements simultaneously, thereby decreasing the time of image reconstruction, which plays an important role in medical diagnostic imaging. The paper presents the preliminary results of computer simulation of the synthetic aperture method combined with the orthogonal Golay sequences in a linear transducer array. The transmission of long waveforms characterized by a particular autocorrelation function allows to increase the total energy of the transmitted signal without increasing the peak pressure. It can also improve the signal-to-noise ratio and increase the visualization depth maintaining the ultrasound image resolution. In the work, the 128-element linear transducer array with a 0.3 mm pitch excited by 8-bits Golay coded sequences as well as one cycle at nominal frequencies of 4 MHz were used. The comparison of 2D ultrasound images of the phantoms is presented to demonstrate the benefits of a coded transmission. The image reconstruction was performed using the synthetic STA algorithm with transmit and receive signals correction based on a single element directivity function.
Go to article

Abstract

Longitudinal and shear ultrasonic wave velocities were measured versus temperature in the viscosity standards of Paragon S8000S, N30000S and Cannon N2700000. The measurements were performed by the through-transmission method at the frequency of 2 MHz. Ultrasonic pulses were sent via polymethyl methacrylate (PMMA) waveguides between the tips of which a small amount of the particular standard liquid was placed. The velocities of longitudinal and shear waves were determined to depend on the viscosity of the liquid and increase with the viscosity.
Go to article

Abstract

Therapeutic and surgical applications of focused ultrasound require monitoring of local temperature rises induced inside tissues. From an economic and practical point of view ultrasonic imaging techniques seem to be the most suitable for the temperature control. This paper presents an implementation of the ultrasonic echoes displacement estimation technique for monitoring of local temperature rise in tissue during its heating by focused ultrasound The results of the estimation were compared to the temperature measured with thermocouple. The obtained results enable to evaluate the temperature fields induced in tissues by pulsed focused ultrasonic beams using non-invasive imaging ultrasound technique
Go to article

Abstract

This paper presents the results of studies on functional possibilities of the optimization of geometric sizes and the design development of specialized resonance concentrating link (concentrator-sonotrode) with enlarged radiating surface. Developed theoretical model allows to determine the value of longitudinal and transverse sizes of each part of concentrating link providing the achievement of required features of the ultrasonic vibrating systems (gain factor of the unit and its resonance frequency). To verify the efficiency of designed model, the geometric sizes of resonance concentrating link were determined using the finite-element complex, which showed that the disagreement did not exceed 10%. The efficiency of proposed model at the determining of size and resonance characteristics of concentrating link was proved by the experiments. Theoretical and experimental studies helped to optimize the size of concentrating link while the vi- brating system developed on its base enabled the enlargement of radiating surface without decreasing the radiation intensity for the realization of technologies of cavitation treatment of liquid media
Go to article

Abstract

Measurements of the hardening process of the selected self-setting sands are presented in the hereby paper. Moulding sands were prepared on the matrix of „Szczakowa” sand of the Sibelco Company. Two resins: phenol-formaldehyde-furfuryl (FF/AF) and urea-formaldehydefurfuryl (MF/AF) were used for making moulding sands. – Methylbenzene-sulphonic acid was applied as a hardener for the moulding sand on FF/AF resin, while paratoluene-sulphonic acid for the moulding sand on MF/AF resin. Both hardeners were used in two concentrations: low – the so-called ‘slow’ hardener and high - ‘fast’ hardener. During investigations, the courses of the hardening process were determined, more accurately changes of the velocity of the ultrasound wave passage through the moulding sand cL = f(t) and changes of the moulding sand hardening degree versus time, Sx = f(t). In addition, the kinetics of the hardening process was determined. Measurements were performed on the research stand for ultrasound investigations.
Go to article

This page uses 'cookies'. Learn more