Nauki Techniczne

Archives of Environmental Protection

Zawartość

Archives of Environmental Protection | 2017 | vol. 43 | No 4 |

Abstrakt

The main goal of this work is to show the new approach to determining safety technological levels (SLs) in terms of water quality and its chemical stability, as well as issues of water corrosion properties in water distribution systems (WDSs), due to the fact that water supply pipes are prone to corrosion. In the paper the methodology of determining the risk associated with threat to technical infrastructure was considered. The concept was studied on the basis of real operational data from the water treatment plant. The probability of exceeding the individual parameters for WTPI is slightly larger than for WTPII, which means that this water treatment process may cause lack of chemical stability in the water supply network. Operators should anticipate in the process of designing water distribution system, using proper materials, as to ensure an adequate level of safety from the water source to the water recipient. It should be noted that it is necessary to adjust the material of internal installation of water supply networks to the parameters of the water. At present, there are no correlations between the designing step and water parameters. It was concluded that to protect the water supply infrastructure, which belongs to critical infrastructure, water company should put more emphasis on distribution of stable water that has not potentially corrosion properties. Some suggestions were made for the protection of WDS and to ensure safety of system functioning and long-term usability of water pipes.

Przejdź do artykułu

Abstrakt

The phenolic compounds are known as priority pollutants, even in low concentrations, as a result of their toxicity and non-biodegradability. For this reason, strict standards have been established for them. In addition, chlorophenols are placed in the 38th to 43th in highest priority order of toxic pollutants. As a consequence, contaminated water or wastewaters with phenolic compounds have to be treated before discharging into the receiving water. In this study, Response Surface Methodology (RSM) has been used in order to optimize the effect of main operational variables responsible for the higher 4-chlorophenol removal by Activated Carbon-Supported Nanoscale Zero Valent Iron (AC/NZVI). A Box-Behnken factorial Design (BBD) with three levels was applied to optimize the initial concentration, time, pH, and adsorbent dose. The characterization of adsorbents was conducted by using SEM-EDS and XRD analyses. Furthermore, the adsorption isotherm and kinetics of 4-chlorophenol on AC and AC/NZVI under various conditions were studied. The model anticipated 100% removal efficiency for AC/NZVI at the optimum concentration (5.48 mg 4-chlorophenol/L), pH (5.44), contact time (44.7 min) and dose (0.65g/L). Analysis of the response surface quadratic model signified that the experiments are accurate and the model is highly significant. Moreover, the synthetic adsorbent is highly efficient in removing of 4-chlorophenol.

Przejdź do artykułu

Abstrakt

This study investigates the estimated adsorption efficiency of artificial Nickel (II) ions with perlite in an aqueous solution using artificial neural networks, based on 140 experimental data sets. Prediction using artificial neural networks is performed by enhancing the adsorption efficiency with the use of Nickel (II) ions, with the initial concentrations ranging from 0.1 mg/L to 10 mg/L, the adsorbent dosage ranging from 0.1 mg to 2 mg, and the varying time of effect ranging from 5 to 30 mins. This study presents an artificial neural network that predicts the adsorption efficiency of Nickel (II) ions with perlite. The best algorithm is determined as a quasi-Newton back-propagation algorithm. The performance of the artificial neural network is determined by coefficient determination (R2), and its architecture is 3-12-1. The prediction shows that there is an outstanding relationship between the experimental data and the predicted values.

Przejdź do artykułu

Abstrakt

Phosphorus removal and recovery from domestic wastewater is urgent nowadays. A novel process of nutrients removal coupled with phosphorus recovery from domestic sewage was proposed and optimization of induced crystallization reaction was performed in this study. The results showed that 92.3% of phosphorus recovery via induced Hydroxyapatite crystallization was achieved at the optimum process parameters: reaction time of 80 min, seed crystal loads of 60 g/L, pH of 8.5, Ca/P mole ratio of 2.0 and 4.0 L/min aeration rate when the PO43--P concentration was 10 mg/L in the influent, displaying an excellent phosphorus recovery performance. Importantly, it was found that the effect of reaction temperature on induced Hydroxyapatite crystallization was slight, thus favoring practical application of phosphorus recovery method described in this study. From these results, the proposed method of induced HAP crystallization to recover phosphorus combined with nutrients removal can be an economical and effective technology, probably favoring the water pollution control and phosphate rock recycle.

Przejdź do artykułu

Abstrakt

The possibility of removing organic compounds from wastewater originating from the photochemical production of printed circuit boards by use of waste acidification and disposal of precipitated photopolymer in the first stage and the UV-Fenton method in a second stage has been presented. To optimize the process of advanced oxidation, the RSM (Response Surface Methodology) for three independent factors was applied, i.e. pH, the concentration of Fe(II) and H2O2 concentration. The use of optimized values of individual parameters in the process of wastewater treatment caused a decrease in the concentration of the organic compounds denoted as COD by approx. 87% in the first stage and approx. 98% after application of both processes. Precipitation and the decomposition of organic compounds was associated with a decrease of wastewater COD to below 100 mg O2/L whereas the initial value was 5550 mg O2/L. Decomposition of organic compounds and verification of the developed model of photopolymers removal was also carried out with use of alternative H2O2 sources i.e. CaO2, MgO2, and Na2CO3·1,5H2O2.

Przejdź do artykułu

Abstrakt

Sewage sludge (municipal, or industrial) treatment is still a problem in so far that it is not satisfactorily resolved in terms of cost and final disposal. Two common forms of sludge disposal are possible; the first being direct disposal on land (including agriculture) and the second being incineration (ash production), although neither of these methods are universally applied. Simplifying the issue, direct sludge disposal on land is seldom applied for sanitary and environmental reasons, while incineration is not popular for financial (high costs) reasons. Very often medium and large wastewater treatment plants apply anaerobic digestion for sludge hygiene principles, reducing the amount to be disposed and for biogas (energy) production. With the progress in sewage biological treatment aiming at nutrient removal, primary sludge has been omitted in the working processes and only surplus activated sludge requires handling. Anaerobic digestion of waste activated sludge (WAS) is more difficult due to the presence of microorganisms, the decomposition of which requires a relatively long time for hydrolysis. In order to upgrade the hydrolysis effects, several different pre-treatment processes have already been developed and introduced. The additional pre-treatment processes applied are aimed at residual sludge bulk mass minimization, shortening of the anaerobic digestion process or higher biogas production, and therefore require additional energy. The water-energy-waste Nexus (treads of) of the benefits and operational difficulties, including energy costs are discussed in this paper. The intensity of pre-treatment processes to upgrade the microorganism’s hydrolysis has crucial implications. Here a low intensity pre-treatment process, alkalisation and hydrodynamic disintegration - hybrid process - were presented in order to achieve sufficient effects of WAS anaerobic digestion. A sludge digestion efficiency increase expressed as 45% biogas additional production and 52% of the total or volatile solids reduction has been confirmed.

Przejdź do artykułu

Abstrakt

The study was aimed at evaluating microbial contamination on the premises of the sewage treatment plant by determining the concentrations of selected groups of airborne microorganisms. Another objective was to determine the antibiotic sensitivity patterns of isolated strains of staphylococci. The research was conducted in a seasonal cycle, by the impaction method using Merck MAS-100 air sampler. Samples were collected at six sites, each representing a different stage of sewage treatment. The susceptibility of isolated staphylococci was assessed with the disc-diffusion method, following the recommendations of the EUCAST. The results indicate that the microbial population in the air of the investigated area was dominated by mold fungi, whose highest average concentration was recorded at site IV located near the final clarifier (7672 CFU•m-3). Heterotrophic bacteria and mannitol-positive staphylococci were the most numerous at locations where sewage undergoes primary treatment. In each subseuqent stage the number of microorganisms emitted into the air from the sewage was lower. Antibiograms show that more than 50% of Staphylococcus spp. exhibited resistance to penicillin and 20% to rifampicin. In addition, 90% of the analyzed strains were sensitive to other antibiotics. The fungal community included the following genera: Cladosporium, Fusarium, Alternaria, Penicillium, Aspergillus, Aureobasidium, and Acremonium.The highest air contamination with all studied groups of microorganisms was recorded at the locations where mechanical sewage treatment was performed. During the subsequent stages lower numbers of heterotrophic bacteria were emitted into the air. The air in the investigated sewage treatment plant did not contain multidrug-resistant staphylococci.

Przejdź do artykułu

Abstrakt

Monitoring of activated sludge flocs may provide important information for effective operation and control of wastewater treatment. The research objective is to demonstrate methodology for activated sludge image processing aimed to describe morphological characteristics of activated sludge flocs. The proposed software- -based method was presented and verified by analysis of several activated sludge samples. The results show high efficiency of image segmentation and floc recognition of more than 94% floc components. The analysis of a series of 50 pictures gives rapid and reliable results and can be performed in an automatic or semiautomatic mode. Given inherent heterogeneity of activated sludge flocs, multiple and repeated sample images capture (processing of 50 pictures at a time, repeated at least 4 times ) is recommended.

Przejdź do artykułu

Abstrakt

The experiment consisted in monitoring the count of moulds and three selected Trichoderma sp. isolates (T1 - Trichoderma atroviride, T2 - Trichoderma harzianum, T3 - Trichoderma harzianum) in vegetable (onion and tomato) waste composted with additives (straw, pig manure). Additionally, the aim of the study was to determine the type of interaction occurring between autochthonous fungi isolated from composts after the end of the thermophilic phase and Trichoderma sp. strains applied in the experiment. Number of microorganisms was determined by the plate method, next the identification was confirmed. The rating scale developed by Mańka was used to determine the type of interactions occurring between microorganisms. The greatest count of moulds in onion waste composts was noted in the object which had simultaneously been inoculated with two strains T1 - T. atroviride and T3 - T. harzianum. The greatest count of moulds was noted in the tomato waste composts inoculated with T2 - T. harzianum strain. Microscope identification revealed that Penicillum sp., Rhizopus sp., Alternaria sp. and Mucor sp. strains were predominant in onion waste composts. In tomato waste composts Penicillium was the predominant genus, followed by Rhizopus. The test of antagonism revealed the inhibitory effect of Trichoderma isolates on most autochthonous strains of moulds. Tomato waste composts proved to be better substrates for the growth and development of Trichoderma sp. isolates. The results of the study show that vegetable waste can be used in agriculture as carriers of antagonistic microorganisms.

Przejdź do artykułu

Abstrakt

The paper presents current reports on kinetics and mechanisms of reactions with mercury which take place in the exhaust gases, discharged from the processes of combustion of solid fuels (coals). The three main stages were considered. The first one, when thermal decomposition of Hg components takes place together with formation of elemental mercury (Hg0). The second one with homogeneous oxidation of Hg0 to Hg2+ by other active components of exhaust gases (e.g. HCl). The third one with heterogeneous reactions of gaseous mercury (the both - elemental and oxidised Hg) and solid particles of fl y ash, leading to generation of particulate-bound mercury (Hgp). Influence of exhaust components and their concentrations, temperature and retention time on the efficiency of mercury oxidation was determined. The issues concerning physical (gas-solid) and chemical speciation of mercury (fractionation Hg0-Hg2+) as well as factors which have influence on the mercury speciation in exhaust gases are discussed in detail.

Przejdź do artykułu

Abstrakt

Irrigation of cultivated plants can be a source of toxic lithium to plants. The data on the effect of lithium uptake on plants are scant, that is why a research was undertaken with the aim to determine maize ability to bioaccumulate lithium. The research was carried out under hydroponic conditions. The experimental design comprised 10 concentrations in solution differing with lithium concentrations in the aqueous solution (ranging from 0.0 to 256.0 mg Li ∙ dm-3 of the nutrient solution). The parameters based on which lithium bioretention by maize was determined were: the yield, lithium concentration in various plant parts, uptake and utilization of this element, tolerance index (TI) and translocation factor (TF), metal concentrations in the above-ground parts index (CI) and bioaccumulation factor (BAF). Depression in yielding of maize occurred only at the highest concentrations of lithium. Lithium concentration was the highest in the roots, lower in the stems and leaves, and the lowest in the inflorescences. The values of tolerance index and EC50 indicated that roots were the most resistant organs to lithium toxicity. The values of translocation factor were indicative of intensive export of lithium from the roots mostly to the stems. The higher uptake of lithium by the above-ground parts than by the roots, which primarily results from the higher yield of these parts of the plants, supports the idea of using maize for lithium phytoremediation.

Przejdź do artykułu

Redakcja

Editors

Editor-in-Chief
Czesława Rosik-Dulewska

Editorial Advisory Board
Michał Bodzek
Katarzyna Juda-Rezler
Korneliusz Miksch

Assistant Editor
Katarzyna Panz

 

Editorial Board:

President:
Lucjan Pawłowski

Members:
Brian A. Bolto (Australia)
Hubert Bril (France)
Bart Van der Bruggen (Belgium)
Zhihong Cao (China)
Pen-Chi Chiang (R.O.C.)
Wolfgang Frenzel (Germany)
Reinhard F. Hüttl (Germany)
Piotr Kowalik (Poland)
Joanna Kyzioł-Komosińska (Poland)
Rajmund Michalski (Poland)
Anuska Mosquera Corral (Spain)
Takashi Nakamura (Japan)
Józef M. Pacyna (Norway)
Wim H. Rulkens (The Nederlands)
Corrado Sarzanini (Italy)
Hans Martin Seip (Norway)
Jan Siuta (Poland)
Jerzy Sobota (Poland)
Joanna Surmacz-Górska (Poland)
Jadwiga Szczepańska (Poland)
Christopher G. Uchrin (USA)
Tomasz Winnicki (Poland)
Xiaoping Zhu (USA)
Jerzy Zwoździak (Poland) 

Kontakt

Institute of Environmental Engineering of the Polish Academy of Sciences
ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze, Poland
Tel.: +48-32-271 64 81      Fax: +48-32-271 74 70
e-mail: aep@ipis.zabrze.pl

Instrukcje dla autorów

Instrukcja dla Autorów
Archives of Environmental Protection jest kwartalnikiem wydawanym wspólnie przez Instytut Podstaw Inżynierii Środowiska PAN oraz Komitet Inżynierii Środowiska PAN. Dzięki współpracy z gronem wybitnych naukowców z całego świata, chcemy oddawać w ręce czytelników starannie wyselekcjonowane, najciekawsze i najbardziej wartościowe teksty, prezentujące najnowszy stan badań w zakresie inżynierii i ochrony środowiska.
Zakres tematyczny
W czasopiśmie publikowane są przede wszystkim oryginalne prace badawcze, dotyczące takich zagadnień jak:
- Ocena jakości powietrza oraz jego oczyszczanie, ochrona przed zanieczyszczeniem powietrza;
- Technologie oczyszczania ścieków oraz przeróbki osadów ściekowych;
- Technologie w gospodarce odpadami w zakresie unieszkodliwiania/odzysku;
- Hydrologia, ocena jakości wód, oczyszczanie wód;
- Ochrona, rewitalizacja i remediacja gleb;
- Przemiany i transport zanieczyszczeń organicznych/nieorganicznych w środowisku;
- Techniki pomiarowe stosowane w inżynierii i monitoringu środowiska;
- Inne zagadnienia wiążące się bezpośrednio z inżynierią i ochroną środowiska.
Przyjmujemy również prace przeglądowe mające charakter „critical review”, czyli krytycznego przeglądu aktualnego stanu wiedzy na dany temat związany bezpośrednio z tematyką ochrony i inżynierii środowiska.
W przypadku braku pewności czy Państwa artykuł mieści się w zakresie tematycznym czasopisma, prosimy o przesłanie abstraktu na adres mailowy: aep@ipis.zabrze.pl
Przygotowanie artykułu
Materiały przekazywane do redakcji powinny być przygotowane zgodnie z podanymi niżej wytycznymi:
• Całość artykułu (wraz z rysunkami, tabelami, streszczeniem oraz bibliografią) nie powinna przekraczać objętości 20 stron. W przypadku przekroczenia wspomnianej objętości artykułu, zalecamy wcześniejszy kontakt z redakcją.
• Praca musi zostać przesłana do redakcji w języku angielskim.
• Artykuł powinien zostać złożony do redakcji w formacie doc lub docx w formie trzech plików: – text.doc – plik zawierający całość tekstu, bez tytułu, słów kluczowych, nazwisk autorów i afiliacji, bez tabel oraz rysunków; – figures.doc – plik zawierający wszystkie rysunki wraz z podpisami; – tables.doc – plik zawierający wszystkie tabele wraz z podpisami;
• Teksty należy przygotować w formacie A4; marginesy: 2,5 cm; czcionka: Times New Roman 12 pkt.; interlinia: 1,5. Tekst powinien zostać podzielony logicznie na rozdziały i podrozdziały zgodnie z ogólnie przyjętymi zasadami redagowania artykułów naukowych. W tekście powinny zostać oznaczone miejsca, w których umieszczone mają zostać tabele i rysunki.
• Opisy rysunków powinny być zwięzłe i czytelne, wykonane pismem odpowiedniej wielkości tak, aby zachować ich czytelność po zmniejszeniu. Prosimy o unikanie umieszczania na rysunkach opisów słownych, które zaleca się podać w podpisie lub tekście artykułu. Wykresy należy zamieszczać bez ramki, ale domknięte również z prawej strony. Legenda do wykresu powinna znajdować się pod nim i być zamieszczona również bez ramki.
• Tabele zawsze powinny być podzielone na kolumny. W przypadku tabel zawierających dużo wyników, muszą być one również podzielone na wiersze aby zachować ich czytelność.
• Literatura w treści artykułu powinna być cytowana poprzez podanie w nawiasie nazwiska i roku publikowania pracy np. (Nowak 2019). W przypadku dwóch autorów cytowanej pracy należy podać obydwa nazwiska połączone „and” oraz rok publikacji np. (Nowak and Kowalski 2019). W przypadku wielu autorów cytowanej pracy należy podać nazwisko pierwszego autora, skrót „et al.” i rok publikowania pracy np. (Kowalski et al. 2019). Gdy w jednym miejscu autor odnosi się do kilku publikacji należy poszczególne cytowania oddzielić przecinkiem np. (Kowalski et al. 2019, Nowak 2019, Nowak and Kowalski 2019). Źródła internetowe powinny być cytowane podobnie jak inne teksty, tj. należy podawać autora i rok powstania danej publikacji.
• Zestawienie cytowanej literatury powinno być zamieszczone na końcu artykułu, uporządkowane alfabetycznie według nazwiska pierwszego z autorów. Wykaz literatury powinien zostać sporządzony według następujących zasad:
1. Czasopismo: Nazwiska i inicjały imion. (rok). Tytuł Artykułu, Nazwa Czasopisma, wolumin, numer, strony, DOI. Przykład: Nowak, S.W., Smith, A.J. & Taylor, K.T. (2019). Title of article, Archives of Environmental Protection, 10, 2, pp. 93–98, DOI: 10.24425/aep.2019.126330.
2. Książka: Nazwiska i inicjały imion. (rok). Tytuł, Nazwa Wydawnictwa, miejsce i rok wydania. Przykład: Kraszewski, J. & Kinecki, K. (2019). Book Title, Prace i Studia, Zabrze 2019.
3. Praca zbiorowa pod redakcją: Nazwiska i inicjały imion autorów tekstu. (rok). Tytuł cytowanego rozdziału, in: Tytuł, nazwiska i inicjały imion redaktora/redaktorów. (Ed)/(Eds). Nazwa wydawnictwa, miejsce wydania, strony. Przykład: Reynor, J. & Taylor, K.T. (2019). Title of chapter, in: Title of the cited book, Kaźmierski, I. & Jasiński, C. (Eds.). Prace i Studia, Zabrze, pp. 145–189.
4. Źródła internetowe: Nazwiska i inicjały imion lub nazwa instytucji publikującej dany tekst. (rok). Tytuł, (adres strony (czas dostępu)). Przykład: Kowalski, M. (2018). Title, (http://www.krakow.pios.gov.pl/publikacje/2009/ (03.12.2018)).
5. Patenty: Orszulik, E. (2009). Palenisko fluidalne, Patent polski: nr PL20070383311 20070910 z 16 marca 2009. Smith, I.M. (1988). U.S. Patent No. 123,445. Washington, D.C.: U.S. Patent and Trademark Office.
6. Materiały publikowane w języku innym niż angielski: Tytuły cytowanych materiałów powinny być przetłumaczone na język angielski. Na końcu przypisu, w nawiasie, powinna znaleźć się informacja na temat języka w jakim artykuł został opublikowany. Przykład:
Nowak, S.W. & Taylor, K.T. (2019). Title of article in English, Journal Name, 10, 2, pp. 93–98, DOI: 10.24425/aep.2019.126330. (in Polish)
Rozdział References powinien zawierać maksymalnie 30 pozycji w przypadku oryginalnych prac badawczych.
Przyjęcie artykułu do redakcji
Złożenie artykułu w redakcji jest równoznaczne z oświadczeniem Autora(ów), że praca nie była dotychczas publikowana i nie jest zgłoszona do publikacji w żadnym innym czasopiśmie. Autorzy przyjmują także odpowiedzialność za uzgodnienie wszystkich praw do jej zgłoszenia. Artykuły należy przesyłać drogą elektroniczną, poprzez Elektroniczny System Obsługi Redakcji, dostępny pod adresem internetowym: www.editorialsystem.com/aep. Prosimy o przesyłanie propozycji przynajmniej 4 potencjalnych recenzentów, w tym 2 z zagranicy, wraz z ich adresami e-mail.
Procedura recenzowania
Wszystkie nadesłane do redakcji artykuły oceniane są przez Kolegium Redakcyjne. Jeśli zostaną pozytywnie zaopiniowane przez co najmniej dwóch redaktorów, Redaktor Naczelna wraz z Redaktorami Działowymi dokonuje wyboru dwóch niezależnych recenzentów spośród autorytetów uznanych w danej dyscyplinie. Recenzenci zostają poproszeni o wykonanie recenzji, otrzymują tekst artykułu (bez danych personalnych autorów) oraz formularze recenzji obowiązujące w czasopiśmie, w uzasadnionych przypadkach poszerzone o dodatkowe pytania dotyczące artykułu. Czas oczekiwania na recenzje wynosi od 1 do 4 miesięcy.
Po zakończeniu procesu recenzowania Autorzy są informowani o jego wynikach oraz – jeżeli obie recenzje są pozytywne – proszeni o naniesienie sugerowanych poprawek. Następnie poprawiona praca jest weryfikowana przez redakcję pod kątem merytorycznym i edytorskim.
Akceptacja artykułu do druku
O przyjęciu pracy do druku decydują: opinie niezależnych recenzentów i akceptacja redakcji. Jeżeli w opinii recenzentów tekst wymaga dużych zmian, redakcja może zrezygnować z jego publikacji pomimo pozytywnych recenzji.
Po przyjęciu artykułu do druku Autorzy zostają o tym poinformowani, a także poproszeni o dokonanie opłaty za publikację oraz o przesłanie na adres redakcji wypełnionego oświadczenia o przekazaniu praw autorskich.
Weryfikacja językowa i korekta autorska
Wszystkie artykuły publikowane na łamach Archives of Environmental Protection przechodzą profesjonalną weryfikację językową. W przypadku bardzo wielu błędów językowych uniemożliwiających zrozumienie tekstu, artykuł zostaje odesłany do autorów z prośbą o ponowne przetłumaczenie wskazanych fragmentów lub – w skrajnych przypadkach – całości tekstu. Po weryfikacji językowej artykuł zostaje przygotowany do druku. Ostatnim etapem procesu publikacji jest korekta autorska. Autorzy otrzymują złożoną wersję artykułu z prośbą o naniesienie ostatnich poprawek.
Opłata za publikację
Redakcja czasopisma nie pobiera opłat za przyjęcie artykułu do procesu redakcyjnego. Koszt opublikowania artykułu w czasopiśmie wynosi:
• 20 EUR/80 zł za stronę czarno-białą lub w odcieniach szarości,
• 30 EUR/120 zł za stronę kolorową.
Wpłat w złotówkach należy dokonywać na nr konta:
Bank BGK.: 20 1130 1091 0003 9111 7820 0001
Wpłat w EUR należy dokonywać na nr konta:
Bank BGK.: 20 1130 1091 0003 9111 7820 0001
IBAN: PL 20 1130 1091 0003 9111 7820 0001
SWIFT: GOSKPLPW
Prosimy o każdorazowe informowanie Redakcji o dokonaniu opłaty za publikację oraz o przesyłanie danych niezbędnych do wystawienia faktury.
Archives of Environmental Protection
Instytut Podstaw Inżynierii Środowiska PAN
ul. M. Skłodowskiej-Curie 34
41-819 Zabrze
Tel.: +48-32-271 64 81
Fax: +48-32-271 74 70

Polityka Open Access

Archives of Environmental Protection jest czasopismem wydawanym w wolnym dostępie na licencji CC BY-NC-SA 4.0.

Archives of Environmental Protection is an open access journal with all content available with no charge in full text version. The journal content is available under the licencse CC BY-NC-SA 4.

Dodatkowe informacje

Abstracting & Indexing

Archives of Environmental Protection is covered by the following services:

AGRICOLA (National Agricultural Library)

AGRIS

Arianta

Baidu Scholar

BazTech

CABI (over 50 subsections)

Chemical Abstracts Service (CAS) - CAplus

Chemical Abstracts Service (CAS) - SciFinder

CNKI Scholar (China National Knowledge Infrastructure)

CNPIEC

Dimensions

DOAJ (Directory of Open Access Journals)

EBSCO (relevant databases)

EBSCO Discovery Service

Engineering Village

FSTA - Food Science & Technology Abstracts

Genamics JournalSeek

GeoArchive

GeoRef

Google Scholar

Index Copernicus

Inspec

Japan Science and Technology Agency (JST)

J-Gate

Journal Citation Reports/Science Edition

JournalTOCs

KESLI-NDSL (Korean National Discovery for Science Leaders)

Microsoft Academic

Naviga (Softweco)

Primo Central (ExLibris)

ProQuest (relevant databases)

Publons

ReadCube

Reaxys

SCOPUS

Sherpa/RoMEO

Summon (Serials Solutions/ProQuest)

TDNet

TEMA Technik und Management

Ulrich's Periodicals Directory/ulrichsweb

WanFang Data

Web of Science - Biological Abstracts

Web of Science - BIOSIS Previews

Web of Science - Science Citation Index Expanded

WorldCat (OCLC)

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji